NOVA Main Breaker Tripped Troubleshooting Steps

Pre-checks
Pre-Check Step 1: Breaker in machine trips immediately without even turning the main power switch on
Pre-Check Step 2: 24V Power Supply Wiring
Pre-Check Step 3: Check the Main Power Cord and connection
Unplug the machine from
the wall and check the main connections:Checking The Main Power Cord
Pre-Check Step 4: Inspect the Main Contactor
Checkout Process:
If nothing is found there, lest test each peripheral in order, do not deviate until the point of cause is found:
Start by:
Turn both switches off (main and laser)


Unplug the fan, Air Assist pump from the back of the machine


Step 1: Test the Main Machine
Plug the machine in at the back and into the wall outlet.

Turn on Main Power switch.

If the breaker trips, the Main Power Feed, Drivers,
36V Drive Power Supply or the Main 24V DC power supply is suspect. Please stop troubleshooting and report this information to the support team at [email protected]
Step 2: Test the LPSU
Turn on the Laser Power switch.

If the breaker doesn't trip, go to the next step.
Step 3: Test the Chiller
Turn the chiller on, let it run for a cycle of compressor
starting, cooling and pumping if possible. This will depend on the water temperature.
If the breaker trips, the chiller is suspect. Please send this information back to [email protected]
If the breaker doesn't trip, go to the next step.
Step 4: Test the Air Assist Pump and Relays\Solenoids
Plug the air assist pump back in to the back of the machine
Press the green "high air assist" button, wait
until it shuts off. Listen for and verify that the pump ran.

Press the green "low air assist" button, wait until it shuts off. Listen for and verify that the pump ran.

Step 4A: Solenoid or Relays for Air Assist
If the breaker doesn't trip, stop the job then go to the next step
Step 5: Test the Exhaust fan
Plug fan back in into the back of the machine

Open the main glass door and ensure that the door interlocks
are not bypassed by you previously(was not instructed to do so in this guide).
Start a job by pressing the Yellow Start/Pause button on the controller screen. The red light, exhaust
and air assist will all come on and there will be an audible tone but the laser head should not move and you will see an
error message on the screen for "machine protected worked paused".


If the fan ramps up, wait about 2 minutes then stop the job by pressing "ESC"
---------------------------------------------------------------------------------------------------------------------------------------------------------------------