Nova DC Laser Tube Pulse Anomaly - Pulse has a Ring and a Dot and looks like a Halo

Troubleshooting guide for Nova laser pulse anomalies showing a halo ring around the pulse dot, including optics inspection and step-by-step pulse checking along the laser path.

Preface: This article covers a pulse anomaly that can occur due to the laser tube output or damaged optics

Red dot is not aligned (purposely) so that the pulse burn mark is easier to see. The pulse burn mark should be concentrated without scatter or halo artifacts. It may not appear perfectly round due to how the tape burns. If it shows signs of scatter or major deformation, it could be a dirty\fouled mirror or bad optic.

Typical pulse dot burn mark

Notice the Halo ring around the pulse dot. That is not normal. This pulse was done at the mirror 3 entry

Malformed pulse with halo ring

Same machine, pulsed into wood right at the exit of the laser tube showing the oversized pulse pattern:

Oversized pulse pattern at tube exit

Before pulsing any further, lets do a visual check of the following:

  1. Laser Tube Exit.
  2. Beam Combiner
    Beam combiner inspection
  3. Mirror 1
    Mirror 1 inspection
  4. Mirror 2
    Mirror 2 inspection

If the above visual checks show that a mirror or lens is dirty, then clean them or replace if necessary.
If no anomalies are found then proceed to the next step of pulse checking along the laser path.

The RECI tube in the Nova 35-80W has a replaceable tube exit lens. Found here and here.

Work through this list to find the source of the issue. Starting at the tube exit and pulsing in the different locations to see when the anomaly shows up. For information on how to Pulse the laser, refer to the reference articles at the bottom of this article.

  1. Pulse on wood at the tube exit between the tube and the beam combiner location
    Pulse location between tube and beam combiner
  2. Pulse on wood at between the beam combiner and mirror 1
  3. Pulse between mirror 1 and mirror 2
  4. Pulse between mirror 2 and mirror 3

If the anomaly shows up in between steps, then the prior device is suspect and should be remediated. You can email [email protected] for more information and guidance.